TCPM
MgO isolation for contact measurement
TCPM
MgO isolation for contact measurement
Main features
- Max. temperature limit: - 40 ... + 310° C for type T - 40 ... + 550° C for type J - 40 ... + 600° C for type E - 40 ... + 1050° C for type K (see table of sheathing diameter used)
- Reference tolerances: IEC 584.2 class 2: for type T: ± 1°C (-40...+133°C) ± 0,0075[t] (t >...+133°C) for type J,E,K: ± 2,5°C (-40...+333°C) ± 0,0075[t] (t >...+333°C)
- Sensitive element with MgO isolation
Technical specifications
- Max. temperature limit:
– 40 … + 310° C for type T
– 40 … + 550° C for type J
– 40 … + 600° C for type E
– 40 … + 1050° C for type K
(see table of sheathing diameter used) - Reference tolerances:
IEC 584.2 class 2:
for type T:
± 1°C (-40…+133°C)
± 0,0075[t] (t >…+133°C)
for type J,E,K:
± 2,5°C (-40…+333°C)
± 0,0075[t] (t >…+333°C) - Sensitive element with MgO isolation
Other products